IEEE39节点系统下设置单点三相短路故障,运用能量函数法分析各支路暂态稳定性指标
English Description:
Single point three-phase short circuit fault is set in IEEE39 bus system, and the transient stability index of each branch is analyzed by using energy function method
Setting single point three phase short circuit fault in IEEE39 bus system